Connector ICD Template
Based on Exercise 7.
Interface identification
- Interface name:
- System / subsystem boundary:
- Revision:
- Owner:
Connector definition
- Connector P/N:
- Mating connector P/N:
- Contact P/Ns:
- Backshell P/N:
- Dust cap P/N:
- Keying / polarization:
Pinout
| Pin | Signal | Source / load | Notes |
|---|---|---|---|
| TBD | TBD | TBD | TBD |
| TBD | TBD | TBD | TBD |
Electrical limits
- Working voltage:
- Current per contact:
- Rating source (datasheet + revision) and derating basis (curve, loaded contacts, ambient, allowable temperature rise):
- Contact size / wire gauge:
- Shielding — type (braid/foil/drain), termination strategy (one end / both ends / 360° backshell), and EMC rationale:
Power / energized-work safety (for power-carrying interfaces)
- Load-break / hot-plug rating: yes / no / explicitly prohibited / not specified
- Mate/unmate under power allowed: yes / no / not specified
- Touch-safe when unmated: yes / no / not specified
- Fuse / overcurrent protection:
- Available fault current:
- Inrush / precharge requirement:
- Ground/PE first-mate / last-break behavior (if applicable):
- Arc/flash hazard note (if applicable):
- Required warning labels / service procedure (if applicable):
Environmental assumptions
- Internal or external:
- Sealing target:
- Vibration / shock:
- Mating cycles:
Assembly / cable requirements
- Torque / assembly notes:
- Cable requirements:
- Test / inspection requirements:
- Workmanship / acceptance standard (e.g. IPC/WHMA-A-620 or program/customer equivalent):
Source / evidence tracking
- Datasheet revision/date:
- Manufacturer drawing revision/date:
- Application specification revision/date:
- Qualified listing checked: yes / no / not applicable
- QPD/QPL reference (if applicable):
- Program/customer requirement reference:
- Derating curve checked: yes / no / not applicable
- Tooling/application spec checked: yes / no / not applicable
| Claim / value relied on | Source document | Rev / date | Requirement type | Verification status | Verified by / date | Open questions / risk if wrong |
|---|---|---|---|---|---|---|
| TBD | TBD | TBD | customer / standard / manufacturer / internal / assumption | verified / assumed / example / TBD | TBD | TBD |
Worked example — M12 A-coded sensor drop
An ICD entry for a 4-pin A-coded M12 sensor interface. Family-level electrical, coding, and sealing values are sourced below; vendor part numbers and project values are marked illustrative. The cable for this interface is worked out in the cable drawing example.
Interface identification
- Interface name: Sensor drop S1
- System / subsystem boundary: field sensor ↔ controller enclosure
- Revision: A (illustrative)
- Owner: (project)
Connector definition
- Connector P/N: M12 A-coded 4-pin female cordset — vendor P/N illustrative
- Mating connector P/N: sensor device M12 A-coded 4-pin male port
- Contact P/Ns: molded cordset (no removable contacts)
- Backshell P/N: molded strain relief (or cable gland for a field-wireable connector)
- Dust cap P/N: M12 protective cap — illustrative
- Keying / polarization: A-coded1
Pinout
| Pin | Signal | Source / load | Notes |
|---|---|---|---|
| 1 | L+ (24 VDC nominal) | Source | Brown |
| 2 | Signal | Per device | White |
| 3 | L− (0 V) | Source | Blue |
| 4 | Signal | Per device | Black |
Pin functions follow the device datasheet; colours per the common A-coded convention.
Electrical limits
- Working voltage: ≤ 250 V per contact (IEC 61076-2-101); application 24 VDC1
- Current per contact: ≤ 4 A (IEC 61076-2-101); application per sensor (typically well under 1 A)1
- Contact size / wire gauge: ≈ 22 AWG / 0.34 mm² (illustrative)
- Shielding: unshielded (typical A-coded sensor); shielded variant if EMI requires
Power / energized-work safety
- Load-break / hot-plug rating: not specified by the datasheet — treat as not load-break
- Mate/unmate under power allowed: no — de-energize the 24 V feed before disconnect (service procedure)
- Touch-safe when unmated: energized (source) side is the female/socket cordset — recessed contacts
- Fuse / overcurrent protection: sensor branch fused upstream (project value)
- Available fault current / inrush: low-power sensor circuit — record per project
- Ground/PE first-mate: n/a (no PE contact in the 4-pin A-coded interface)
Environmental assumptions
- Internal or external: external field drop
- Sealing target: IP67 when mated and torqued; unmated only when capped2
- Vibration / shock: per application
- Mating cycles: per datasheet (screw-lock; commonly ≥ 100)
Assembly / cable requirements
- Torque / assembly notes: coupling torque per datasheet (e.g. Turck specifies 0.8–1.0 N·m) — verify2
- Cable requirements: PUR jacket, OD within the gland range; see the cable drawing example
- Test / inspection requirements: continuity, insulation resistance, coupling-torque check
- Workmanship / acceptance: IPC/WHMA-A-620 or the program/customer equivalent; molded cordset — incoming inspection (illustrative)
Source / evidence tracking
- IEC 61076-2-101 listing (coding, ≤ 4 A / ≤ 250 V class) — verified, cited in Sources below; record the edition/date you check
- Turck torque example (0.8–1.0 N·m) — verified example, manufacturer-specific; replace with your vendor's figure
- Vendor P/N, cable OD, revision fields — example-only (illustrative); qualified listing: not applicable for this commercial sensor interface
- Derating curve checked: not applicable at sensor current — record it for anything approaching the contact rating