Cable Drawing Template
Based on Exercise 6.
Cable endpoints
- Connector A:
- Connector B:
Conductor schedule
| Wire | Color | Gauge | Twisted pair | Shield / drain treatment | End A | End B | Notes |
|---|---|---|---|---|---|---|---|
| TBD | TBD | TBD | TBD | TBD | TBD | TBD | TBD |
| TBD | TBD | TBD | TBD | TBD | TBD | TBD | TBD |
Cable construction
- Cable jacket:
- Labels:
- Length tolerance:
- Notes:
Test requirements
- Continuity:
- Pinout verification:
- Shield / drain verification:
- Pull-test requirement:
- Crimp spec / strip length reference (from the contact application spec):
- Workmanship / acceptance standard (e.g. IPC/WHMA-A-620 class, or the program/customer equivalent):
- Additional test requirements:
Shield strategy (if shielded)
- Shield required: yes / no
- Shield type: braid / foil / drain / combination
- Shield termination: one end / both ends / 360° backshell / capacitive / other
- Connector shell bonded to chassis: yes / no / not applicable
- EMC requirement or rationale (noise problem, frequency range of concern):
- Test / verification method:
- Grounding owner / reviewer:
Source / evidence tracking
| Claim / value relied on | Source document | Rev / date | Requirement type | Verification status | Verified by / date | Open questions / risk if wrong |
|---|---|---|---|---|---|---|
| TBD | TBD | TBD | customer / standard / manufacturer / internal / assumption | verified / assumed / example / TBD | TBD | TBD |
Worked example — M12 A-coded sensor cable
A double-ended M12 A-coded sensor cordset. Family-level electrical, coding, and sealing values are sourced below; project- and vendor-specific fields (exact part number, length, cable OD) are marked illustrative — fill them from the parts you actually buy. See the matching ICD worked example.
Cable endpoints
- Connector A: M12 A-coded, 4-pin, female (socket), straight — to the sensor's device port
- Connector B: M12 A-coded, 4-pin, male (pin), straight — to the panel receptacle
Conductor schedule
| Wire | Color | Gauge | Twisted pair | Shield / drain | End A pin | End B pin | Notes |
|---|---|---|---|---|---|---|---|
| 1 | Brown (BN) | 22 AWG (0.34 mm²) | — | — | 1 | 1 | L+ (24 VDC nominal) |
| 2 | White (WH) | 22 AWG (0.34 mm²) | — | — | 2 | 2 | Signal — per device datasheet |
| 3 | Blue (BU) | 22 AWG (0.34 mm²) | — | — | 3 | 3 | L− (0 V) |
| 4 | Black (BK) | 22 AWG (0.34 mm²) | — | — | 4 | 4 | Signal — per device datasheet |
Wire colours follow the common A-coded 4-pin convention; confirm pin functions against the device datasheet and the cordset drawing.
Cable construction
- Cable jacket: PUR, Ø ≈ 5–6 mm (illustrative — must fall inside the gland/clamp range for a field-wireable connector)
- Labels: both ends, per drawing
- Length tolerance: ±25 mm (illustrative)
- Notes: A-coded is rated ≤ 4 A per contact and ≤ 250 V (IEC 61076-2-101);1 IP67 applies only when mated and correctly torqued2
Test requirements
- Continuity: pin 1→1, 2→2, 3→3, 4→4
- Pinout verification: against the schedule above
- Shield / drain verification: n/a (unshielded); add if a shielded variant is used
- Workmanship / acceptance: IPC/WHMA-A-620 or the program/customer equivalent — molded cordset, incoming inspection (illustrative)
- Additional: insulation resistance; coupling-torque check2
Shield strategy / evidence
- Shield: none (unshielded A-coded sensor cordset); revisit with an EMC rationale if a shielded variant is used
- Evidence: family electrical/coding/sealing values — IEC 61076-2-101 listing + M12 torque example, verified (Sources below); all fields marked (illustrative) — example-only, replace from the parts you actually buy